WOLFRAM SYSTEM MODELER

CCCV_CellRC

Charge a transient cell with constant current - constant voltage characteristic

Diagram

Wolfram Language

In[1]:=
SystemModel["Modelica.Electrical.Batteries.Examples.CCCV_CellRC"]
Out[1]:=

Information

This information is part of the Modelica Standard Library maintained by the Modelica Association.

A single transient cell depleted to SOC = 0.1 is recharged with a CC-CV charger. Charging current in CC mode is 5C which means the battery is theoretically nearly fulled charged after 0.9*3600 s/5 = 648 s and the charger switches to CV mode. Simulate for 1200 s and plot cell.cellBus.soc versus time.

Parameters (1)

cellData

Value:

Type: ExampleData

Description: Cell data

Components (6)

cellData

Type: ExampleData

Description: Cell data

cccvCharger

Type: CCCVcharger

Description: Charger with constant current - constant voltage characteristic

ground

Type: Ground

Description: Ground node

cell

Type: CellRC

Description: Cell with measurement

multiSensor

Type: MultiSensor

Description: Sensor to measure current, voltage and power

energy

Type: Integrator

Description: Output the integral of the input signal with optional reset