WOLFRAM SYSTEM MODELER
AmplifierAmplifier using an op-amp to amplify an AC signal. |
![]() |
SystemModel["IndustryExamples.Other.AmplifierReliability.Amplifier"]
This model shows how to combine reliability information and Modelica models.
In order to get the full experience of this example, you need the following:
These pages show an overview of the example. For the full example, open the accompanying notebook AmplifierReliability.nb.
The annotations are edited in the reliability view. Here a reliability block diagram is created by selecting "ReliabilityDistribution" from the Distribution drop-down menu, and a series connection has been entered in the Parameters text field.
The individual components have their own annotations.
This is a model of an operational amplifier. It is based on Modelica.Electrical.Analog.AmplifierWithOpAmpDetailed.
This domain example is an informational resource made freely available by Wolfram Research.
All content in this bundle is licensed under the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 Unported License. By accessing the content or using it in any way, you accept and agree to be bound by the terms of this license. If you do not agree to these Terms of Use, you may not use this content. Wolfram Research reserves the right to change, modify, add to, or remove portions of these Terms of Use at any time without notice. Please refer back to www.wolfram.com for the latest Terms of Use.
A summary of the licensing terms can be found at:
http://creativecommons.org/licenses/by-nc-sa/3.0
The full legal code can be found at:
http://creativecommons.org/licenses/by-nc-sa/3.0/legalcode
![]() |
opAmp |
Type: OpAmp |
---|---|---|
![]() |
resistor |
Type: Resistor |
![]() |
resistor1 |
Type: Resistor |
![]() |
sineVoltage |
Type: SineVoltage |
![]() |
ground |
Type: Ground |
![]() |
constantVoltage |
Type: ConstantVoltage |
![]() |
constantVoltage1 |
Type: ConstantVoltage |
![]() |
resistor2 |
Type: Resistor |
![]() |
ground1 |
Type: Ground |