WOLFRAM SYSTEM MODELER

ControlledCloserWithArc

Controlled ideal electrical closer with simple arc model

Wolfram Language

In[1]:=
SystemModel["Modelica.Electrical.Analog.Ideal.ControlledCloserWithArc"]
Out[1]:=

Information

This information is part of the Modelica Standard Library maintained by the Modelica Association.

This model is an extension to the ControlledIdealClosingSwitch.

For details of the arc effect, see partial model IdealSwitchWithArc.

Parameters (8)

useHeatPort

Value: false

Type: Boolean

Description: = true, if heatPort is enabled

T

Value: 293.15

Type: Temperature (K)

Description: Fixed device temperature if useHeatPort = false

Ron

Value: 1E-5

Type: Resistance (Ω)

Description: Closed switch resistance

Goff

Value: 1E-5

Type: Conductance (S)

Description: Opened switch conductance

V0

Value:

Type: Voltage (V)

Description: Initial arc voltage

dVdt

Value:

Type: VoltageSlope (V/s)

Description: Arc voltage slope

Vmax

Value:

Type: Voltage (V)

Description: Max. arc voltage

level

Value: 0.5

Type: Voltage (V)

Description: Switch level

Connectors (4)

p

Type: PositivePin

Description: Positive electrical pin

n

Type: NegativePin

Description: Negative electrical pin

heatPort

Type: HeatPort_a

Description: Conditional heat port

control

Type: Pin

Description: Control pin: control.v > level switch closed, otherwise switch open

Used in Examples (1)

ControlledSwitchWithArc

Modelica.Electrical.Analog.Examples

Comparison of controlled switch models both with and without arc

Revisions

  • February 7, 2016 by Anton Haumer
    extending from partial IdealSwitchWithArc
  • May, 2009 by Anton Haumer
    initially implemented