WOLFRAM SYSTEM MODELER

IdealIntermediateSwitch

Ideal intermediate switch

Wolfram Language

In[1]:=
SystemModel["Modelica.Electrical.Analog.Ideal.IdealIntermediateSwitch"]
Out[1]:=

Information

This information is part of the Modelica Standard Library maintained by the Modelica Association.

The intermediate switch has four switching contact pins p1, p2, n1, and n2. The switching behaviour is controlled by the input signal control. If control is true, the pin p1 is connected to the pin n2, and the pin p2 is connected to the pin n1. Otherwise,if control is false, the pin p1 is connected to n1, and the pin p2 is connected to n2.

IdealIntermediateSwitch1.png

In order to prevent singularities during switching, the opened switch has a (very low) conductance Goff and the closed switch has a (very low) resistance Ron.

IdealIntermediateSwitch2.png

The limiting case is also allowed, i.e., the resistance Ron of the closed switch could be exactly zero and the conductance Goff of the open switch could be also exactly zero. Note, there are circuits, where a description with zero Ron or zero Goff is not possible.

Please note: In case of useHeatPort=true the temperature dependence of the electrical behavior is not modelled. The parameters are not temperature dependent.

Parameters (4)

useHeatPort

Value: false

Type: Boolean

Description: = true, if heatPort is enabled

T

Value: 293.15

Type: Temperature (K)

Description: Fixed device temperature if useHeatPort = false

Ron

Value: 1e-5

Type: Resistance (Ω)

Description: Closed switch resistance

Goff

Value: 1e-5

Type: Conductance (S)

Description: Opened switch conductance

Connectors (6)

heatPort

Type: HeatPort_a

Description: Conditional heat port

p1

Type: PositivePin

Description: Positive pin of an electrical component

p2

Type: PositivePin

Description: Positive pin of an electrical component

n1

Type: NegativePin

Description: Negative pin of an electrical component

n2

Type: NegativePin

Description: Negative pin of an electrical component

control

Type: BooleanInput

Description: true => p1--n2, p2--n1 connected, otherwise p1--n1, p2--n2 connected

Used in Components (1)

IdealIntermediateSwitch

Modelica.Electrical.Polyphase.Ideal

Polyphase ideal intermediate switch

Revisions

  • March 11, 2009 by Christoph Clauss
    conditional heat port added
  • 1998 by Christoph Clauss
    initially implemented