WOLFRAM SYSTEM MODELER
PartialThermalAmbientDCMachinesPartial thermal ambience for DC machines |
|
SystemModel["Modelica.Electrical.Machines.Interfaces.DCMachines.PartialThermalAmbientDCMachines"]

This information is part of the Modelica Standard Library maintained by the Modelica Association.
Partial thermal ambience for induction machines| useTemperatureInputs |
Value: false Type: Boolean Description: If true, temperature inputs are used; else, temperatures are constant |
|---|---|
| Ta |
Value: Type: Temperature (K) Description: Temperature of armature |
| Q_flowArmature |
Default Value: temperatureArmature.port.Q_flow Type: HeatFlowRate (W) Description: Heat flow rate of armature |
|---|---|
| Q_flowCore |
Default Value: temperatureCore.port.Q_flow Type: HeatFlowRate (W) Description: Heat flow rate of core losses |
| Q_flowStrayLoad |
Default Value: temperatureStrayLoad.port.Q_flow Type: HeatFlowRate (W) Description: Heat flow rate of stray load losses |
| Q_flowFriction |
Default Value: temperatureFriction.port.Q_flow Type: HeatFlowRate (W) Description: Heat flow rate of friction losses |
| Q_flowBrush |
Default Value: temperatureBrush.port.Q_flow Type: HeatFlowRate (W) Description: Heat flow rate of brushes |
| thermalPort |
Type: PartialThermalPortDCMachines Description: Partial thermal port of DC machines |
|
|---|---|---|
| TArmature |
Type: RealInput Description: Temperature of armature |
| temperatureArmature |
Type: PrescribedTemperature Description: Variable temperature boundary condition in Kelvin |
|
|---|---|---|
| temperatureCore |
Type: FixedTemperature Description: Fixed temperature boundary condition in Kelvin |
|
| temperatureStrayLoad |
Type: FixedTemperature Description: Fixed temperature boundary condition in Kelvin |
|
| temperatureFriction |
Type: FixedTemperature Description: Fixed temperature boundary condition in Kelvin |
|
| constTa |
Type: Constant Description: Generate constant signal of type Real |
|
| temperatureBrush |
Type: FixedTemperature Description: Fixed temperature boundary condition in Kelvin |
|
Modelica.Electrical.Machines.Interfaces Partial model for DC machine |
|
Modelica.Electrical.Machines.Thermal.DCMachines Thermal ambient for DC machine with compound excitation |
|
|
Modelica.Electrical.Machines.Thermal.DCMachines Thermal ambient for DC machine with series excitation |
|
|
Modelica.Electrical.Machines.Thermal.DCMachines Thermal ambient for DC machine with electrical excitation |
|
|
Modelica.Electrical.Machines.Thermal.DCMachines Thermal ambient for DC machine with permanent magnets |