WOLFRAM SYSTEM MODELER

PartialThermalAmbientDCMachines

Partial thermal ambience for DC machines

Diagram

Wolfram Language

In[1]:=
SystemModel["Modelica.Electrical.Machines.Interfaces.DCMachines.PartialThermalAmbientDCMachines"]
Out[1]:=

Information

This information is part of the Modelica Standard Library maintained by the Modelica Association.

Partial thermal ambience for induction machines

Parameters (2)

useTemperatureInputs

Value: false

Type: Boolean

Description: If true, temperature inputs are used; else, temperatures are constant

Ta

Value:

Type: Temperature (K)

Description: Temperature of armature

Outputs (5)

Q_flowArmature

Default Value: temperatureArmature.port.Q_flow

Type: HeatFlowRate (W)

Description: Heat flow rate of armature

Q_flowCore

Default Value: temperatureCore.port.Q_flow

Type: HeatFlowRate (W)

Description: Heat flow rate of core losses

Q_flowStrayLoad

Default Value: temperatureStrayLoad.port.Q_flow

Type: HeatFlowRate (W)

Description: Heat flow rate of stray load losses

Q_flowFriction

Default Value: temperatureFriction.port.Q_flow

Type: HeatFlowRate (W)

Description: Heat flow rate of friction losses

Q_flowBrush

Default Value: temperatureBrush.port.Q_flow

Type: HeatFlowRate (W)

Description: Heat flow rate of brushes

Connectors (2)

thermalPort

Type: PartialThermalPortDCMachines

Description: Partial thermal port of DC machines

TArmature

Type: RealInput

Description: Temperature of armature

Components (6)

temperatureArmature

Type: PrescribedTemperature

Description: Variable temperature boundary condition in Kelvin

temperatureCore

Type: FixedTemperature

Description: Fixed temperature boundary condition in Kelvin

temperatureStrayLoad

Type: FixedTemperature

Description: Fixed temperature boundary condition in Kelvin

temperatureFriction

Type: FixedTemperature

Description: Fixed temperature boundary condition in Kelvin

constTa

Type: Constant

Description: Generate constant signal of type Real

temperatureBrush

Type: FixedTemperature

Description: Fixed temperature boundary condition in Kelvin

Used in Components (1)

PartialBasicDCMachine

Modelica.Electrical.Machines.Interfaces

Partial model for DC machine

Extended by (4)

ThermalAmbientDCCE

Modelica.Electrical.Machines.Thermal.DCMachines

Thermal ambient for DC machine with compound excitation

ThermalAmbientDCSE

Modelica.Electrical.Machines.Thermal.DCMachines

Thermal ambient for DC machine with series excitation

ThermalAmbientDCEE

Modelica.Electrical.Machines.Thermal.DCMachines

Thermal ambient for DC machine with electrical excitation

ThermalAmbientDCPM

Modelica.Electrical.Machines.Thermal.DCMachines

Thermal ambient for DC machine with permanent magnets