This information is part of the Modelica Standard Library maintained by the Modelica Association.

Model of voltage drop and losses of carbon brushes. For currents between -ILinear and ILinear the voltage drop shows a linear behavior as depicted in Fig. 1. For positive currents greater or equal than ILinear the voltage drop equals V. For negative currents less or equal than -ILinear the voltage drop equals -V.

brush.png
Fig. 1: Model of voltage drop of carbon brushes

Note

The voltage drop v is the total voltage drop of all series connected brushes.

See also

BrushParameters

If it is desired to neglect brush losses, set brushParameters.V = 0 (this is the default).

Parameters (2)

useHeatPort

Value: false

Type: Boolean

Description: = true, if heatPort is enabled

brushParameters

Value:

Type: BrushParameters

Description: Brush loss parameters

Connectors (3)

p

Type: PositivePin

Description: Positive electrical pin

n

Type: NegativePin

Description: Negative electrical pin

heatPort

Type: HeatPort_a

Description: Optional port to which dissipated losses are transported in form of heat

Components (1)

brushParameters

Type: BrushParameters

Description: Brush loss parameters

Used in Components (5)

SM_ElectricalExcited

Modelica.Electrical.Machines.BasicMachines.SynchronousMachines

Electrical excited synchronous machine with damper cage

Brush

Modelica.Electrical.Machines.Losses.InductionMachines

Model considering voltage drop of carbon brushes

PartialBasicDCMachine

Modelica.Electrical.Machines.Interfaces

Partial model for DC machine

SM_ElectricalExcited

Modelica.Magnetic.FundamentalWave.BasicMachines.SynchronousMachines

Electrical excited synchronous machine with optional damper cage

SM_ElectricalExcited

Modelica.Magnetic.QuasiStatic.FundamentalWave.BasicMachines.SynchronousMachines

Electrical excited synchronous machine with optional damper cage