WOLFRAM SYSTEM MODELER

InductionMachineData

Common parameters for induction machines

Wolfram Language

In[1]:=
SystemModel["Modelica.Electrical.Machines.Utilities.ParameterRecords.InductionMachineData"]
Out[1]:=

Information

This information is part of the Modelica Standard Library maintained by the Modelica Association.

Basic parameters of induction machines are predefined with default values.

Parameters (14)

m

Value: 3

Type: Integer

Description: Number of phases

Jr

Value: 0.29

Type: Inertia (kg⋅m²)

Description: Rotor's moment of inertia

Js

Value: Jr

Type: Inertia (kg⋅m²)

Description: Stator's moment of inertia

p

Value: 2

Type: Integer

Description: Number of pole pairs (Integer)

fsNominal

Value: 50

Type: Frequency (Hz)

Description: Nominal frequency

Rs

Value: 0.03

Type: Resistance (Ω)

Description: Stator resistance per phase at TRef

TsRef

Value: 293.15

Type: Temperature (K)

Description: Reference temperature of stator resistance

alpha20s

Value: 0

Type: LinearTemperatureCoefficient20 (1/K)

Description: Temperature coefficient of stator resistance at 20 degC

effectiveStatorTurns

Value: 1

Type: Real

Description: Effective number of stator turns

Lszero

Value: Lssigma

Type: Inductance (H)

Description: Stator zero sequence inductance

Lssigma

Value: 3 * (1 - sqrt(1 - 0.0667)) / (2 * pi * fsNominal)

Type: Inductance (H)

Description: Stator stray inductance per phase

frictionParameters

Value:

Type: FrictionParameters

Description: Friction loss parameter record

statorCoreParameters

Value:

Type: CoreParameters

Description: Stator core loss parameter record; all parameters refer to stator side

strayLoadParameters

Value:

Type: StrayLoadParameters

Description: Stray load losses

Components (3)

frictionParameters

Type: FrictionParameters

Description: Friction loss parameter record

statorCoreParameters

Type: CoreParameters

Description: Stator core loss parameter record; all parameters refer to stator side

strayLoadParameters

Type: StrayLoadParameters

Description: Stray load losses

Extended by (3)

SM_ReluctanceRotorData

Modelica.Electrical.Machines.Utilities.ParameterRecords

Common parameters for synchronous machines with reluctance rotor

IM_SlipRingData

Modelica.Electrical.Machines.Utilities.ParameterRecords

Common parameters for induction machines with slip ring

IM_SquirrelCageData

Modelica.Electrical.Machines.Utilities.ParameterRecords

Common parameters for induction machines with squirrel cage