WOLFRAM SYSTEMMODELER

ThyristorCenterTapmPulse_RLV

2*m pulse thyristor rectifier with center tap and R-L load and voltage

Diagram

Wolfram Language

In[1]:=
Click for copyable input
SystemModel["Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierCenterTapmPulse.ThyristorCenterTapmPulse_RLV"]
Out[1]:=

Information

This information is part of the Modelica Standard Library maintained by the Modelica Association.

This example shows a controlled m pulse center tap rectifier with R-L load including DC voltage source, where m is the number of phases. The additional DC voltage source in this example enables negative average load voltages.

Plot current currentSensor.i, average current meanCurrent.y, voltage voltageSensor.v and average voltage meanVoltage.v.

Parameters (7)

m

Value: 3

Type: Integer

Description: Number of phases

Vrms

Value: 110

Type: Voltage (V)

Description: RMS supply voltage

f

Value: 50

Type: Frequency (Hz)

Description: Frequency

constantFiringAngle

Value: 30 * pi / 180

Type: Angle (rad)

Description: Firing angle

R

Value: 20

Type: Resistance (Ω)

Description: Load resistance

L

Value: 1

Type: Inductance (H)

Description: Load resistance

VDC

Value: -50

Type: Voltage (V)

Description: DC load offset voltage

Components (13)

ground

Type: Ground

Description:

star

Type: Star

Description:

sineVoltage_p

Type: SineVoltage

Description:

rectifier

Type: ThyristorCenterTapmPulse

Description:

voltagesensor

Type: VoltageSensor

Description:

meanVoltage

Type: Mean

Description:

rootMeanSquareVoltage

Type: RootMeanSquare

Description:

currentSensor

Type: CurrentSensor

Description:

meanCurrent

Type: Mean

Description:

pulsem

Type: VoltageBridge2mPulse

Description:

resistor

Type: Resistor

Description:

inductor

Type: Inductor

Description:

constantVoltage

Type: ConstantVoltage

Description: