RoomCO2Demonstrates a room volume with CO2 accumulation |
SystemModel["Modelica.Fluid.Examples.TraceSubstances.RoomCO2"]
This information is part of the Modelica Standard Library maintained by the Modelica Association.
This example consists of a volume with a carbon dioxide concentration that corresponds to 1.519E-3 kg/kg, which is equal to 1000 PPM. There is a fresh air stream with a carbon dioxide concentration of about 300 PPM. The fresh air stream is such that the air exchange rate is about 5 air changes per hour. After 1 hour of ventilation, the volume's carbon dioxide concentration is close to the concentration of the fresh air.
The nominal value for the trace substance is set to C_nominal={1.519E-3}
.
This scales the residual equations that are used by the solver to the right order
of magnitude.