WOLFRAM SYSTEM MODELER
IdealFlowHeatTransferIdealHeatTransfer: Ideal heat transfer without thermal resistance |
SystemModel["Modelica.Fluid.Pipes.BaseClasses.HeatTransfer.IdealFlowHeatTransfer"]
This information is part of the Modelica Standard Library maintained by the Modelica Association.
Ideal heat transfer without thermal resistance.n |
Value: 1 Type: Integer Description: Number of heat transfer segments |
---|---|
use_k |
Value: false Type: Boolean Description: = true to use k value for thermal isolation |
k |
Value: 0 Type: CoefficientOfHeatTransfer (W/(m²⋅K)) Description: Heat transfer coefficient to ambient |
T_ambient |
Value: system.T_ambient Type: Temperature (K) Description: Ambient temperature |
nParallel |
Value: Type: Real Description: Number of identical parallel flow devices |
states |
Type: ThermodynamicState[n] Description: Thermodynamic states of flow segments |
---|---|
surfaceAreas |
Type: Area[n] (m²) Description: Heat transfer areas |
vs |
Type: Velocity[n] (m/s) Description: Mean velocities of fluid flow in segments |
lengths |
Type: Length[n] (m) Description: Lengths along flow path |
dimensions |
Type: Length[n] (m) Description: Characteristic dimensions for fluid flow (diameter for pipe flow) |
roughnesses |
Type: Roughness[n] (m) Description: Average heights of surface asperities |
Q_flows |
Type: HeatFlowRate[n] (W) Description: Heat flow rates |
---|
heatPorts |
Type: HeatPorts_a[n] Description: Heat port to component boundary |
---|
states |
Type: ThermodynamicState[n] Description: Thermodynamic states of flow segments |
|
---|---|---|
system |
Type: System Description: System wide properties |
Modelica.Fluid.Pipes.DynamicPipe Wall heat transfer |
|
Modelica.Fluid.Examples.HeatExchanger.BaseClasses.BasicHX Heat transfer model |
|
Modelica.Fluid.Examples.HeatExchanger.BaseClasses.BasicHX Heat transfer model |