WOLFRAM SYSTEM MODELER
pressureLoss_m_flow_staticHeadReturn pressure loss dp as function of mass flow rate m_flow, i.e., dp = f(m_flow), due to wall friction and static head |
SystemModel["Modelica.Fluid.Pipes.BaseClasses.WallFriction.LaminarAndQuadraticTurbulent.pressureLoss_m_flow_staticHead"]
m_flow |
Type: MassFlowRate (kg/s) Description: Mass flow rate from port_a to port_b |
---|---|
rho_a |
Type: Density (kg/m³) Description: Density at port_a |
rho_b |
Type: Density (kg/m³) Description: Density at port_b |
mu_a |
Type: DynamicViscosity (Pa⋅s) Description: Dynamic viscosity at port_a (dummy if use_mu = false) |
mu_b |
Type: DynamicViscosity (Pa⋅s) Description: Dynamic viscosity at port_b (dummy if use_mu = false) |
length |
Type: Length (m) Description: Length of pipe |
diameter |
Type: Diameter (m) Description: Inner (hydraulic) diameter of pipe |
g_times_height_ab |
Type: Real (m²/s²) Description: Gravity times (Height(port_b) - Height(port_a)) |
crossArea |
Default Value: pi * diameter ^ 2 / 4 Type: Area (m²) Description: Inner cross section area |
roughness |
Default Value: 2.5e-5 Type: Roughness (m) Description: Absolute roughness of pipe, with a default for a smooth steel pipe (dummy if use_roughness = false) |
m_flow_small |
Default Value: 0.01 Type: MassFlowRate (kg/s) Description: Regularization of zero flow if |m_flow| < m_flow_small (dummy if use_m_flow_small = false) |
Re_turbulent |
Default Value: 4000 Type: ReynoldsNumber Description: Turbulent flow if Re >= Re_turbulent (dummy if use_Re_turbulent = false) |
dp |
Type: Pressure (Pa) Description: Pressure loss (dp = port_a.p - port_b.p) |
---|