WOLFRAM SYSTEM MODELER

BaseData

Hysteresis table data

Wolfram Language

In[1]:=
SystemModel["Modelica.Magnetic.FluxTubes.Material.HysteresisTableData.BaseData"]
Out[1]:=

Information

This information is part of the Modelica Standard Library maintained by the Modelica Association.

Parameters (3)

tabris

Value: [-10000000, -0.8000; -1000, -0.8000; -300, -0.8000; -200, -0.8000; -190, -0.8000; -180, -0.8000; -160, -0.7999; -150, -0.7998; -140, -0.7997; -130, -0.7996; -120, -0.7993; -110, -0.7989; -100, -0.7982; -90, -0.7971; -80, -0.7953; -70, -0.7924; -60, -0.7878; -50, -0.7802; -40, -0.7680; -30, -0.7486; -20, -0.7180; -10, -0.6708; 0, -0.6000; 10, -0.4983; 20, -0.3611; 30, -0.1908; 40, 0.0000; 50, 0.1908; 60, 0.3611; 70, 0.4983; 80, 0.6000; 90, 0.6708; 100, 0.7180; 110, 0.7486; 120, 0.7680; 130, 0.7802; 140, 0.7878; 150, 0.7924; 160, 0.7953; 170, 0.7971; 180, 0.7982; 190, 0.7989; 200, 0.7993; 300, 0.8000; 1000, 0.8000; 10000000, 0.8000]

Type: Real[:,:]

Description: Table data of the rising (lower) branch of the hysteresis envelope curve (H, B)

tabfal

Value: [-10000000, -0.8000; -1000, -0.8000; -300, -0.8000; -200, -0.7993; -190, -0.7989; -180, -0.7982; -170, -0.7971; -160, -0.7953; -150, -0.7924; -140, -0.7878; -130, -0.7802; -120, -0.7680; -110, -0.7486; -100, -0.7180; -90, -0.6708; -80, -0.6000; -70, -0.4983; -60, -0.3611; -50, -0.1908; -40, 0.0000; -30, 0.1908; -20, 0.3611; -10, 0.4983; 0, 0.6000; 10, 0.6708; 20, 0.7180; 30, 0.7486; 40, 0.7680; 50, 0.7802; 60, 0.7878; 70, 0.7924; 80, 0.7953; 90, 0.7971; 100, 0.7982; 110, 0.7989; 120, 0.7993; 130, 0.7996; 140, 0.7997; 150, 0.7998; 160, 0.7999; 180, 0.8000; 190, 0.8000; 200, 0.8000; 300, 0.8000; 1000, 0.8000; 10000000, 0.8000]

Type: Real[:,:]

Description: Table data of the falling (upper) branch of the hysteresis envelope curve (H, B)

sigma

Value: 1

Type: Conductivity (S/m)

Description: Electric conductivity

Used in Components (1)

GenericHystTellinenTable

Modelica.Magnetic.FluxTubes.Shapes.HysteresisAndMagnets

Generic flux tube with ferromagnetic hysteresis based on the Tellinen model and table data

Extended by (8)

M800_65A

Modelica.Magnetic.FluxTubes.Material.HysteresisTableData

M800-65A

M400_50AP

Modelica.Magnetic.FluxTubes.Material.HysteresisTableData

M400-50AP

M400_50A

Modelica.Magnetic.FluxTubes.Material.HysteresisTableData

M400-50A

M330_50A

Modelica.Magnetic.FluxTubes.Material.HysteresisTableData

M330-50A

M270_50A

Modelica.Magnetic.FluxTubes.Material.HysteresisTableData

M270-50A

Vacodur50

Modelica.Magnetic.FluxTubes.Material.HysteresisTableData

Vacodur50

Vacoflux48

Modelica.Magnetic.FluxTubes.Material.HysteresisTableData

Vacoflux48

Vacoflux17

Modelica.Magnetic.FluxTubes.Material.HysteresisTableData

Vacoflux17