WOLFRAM SYSTEM MODELER
PressureIncreaseEnforces constant pressure increase |
SystemModel["Modelica.Thermal.FluidHeatFlow.Sources.PressureIncrease"]
This information is part of the Modelica Standard Library maintained by the Modelica Association.
Fan resp. pump with constant pressure increase. Mass resp. volume flow is the response of the whole system.
Coolant's temperature and enthalpy flow are not affected.
Setting parameter m (mass of medium within fan/pump) to zero leads to neglect of temperature transient cv*m*der(T).
Thermodynamic equations are defined by BaseClasses.TwoPort.
medium |
Value: FluidHeatFlow.Media.Medium() Type: Medium Description: Medium in the component |
---|---|
m |
Value: Type: Mass (kg) Description: Mass of medium |
T0 |
Value: Type: Temperature (K) Description: Initial temperature of medium |
T0fixed |
Value: false Type: Boolean Description: Initial temperature guess value or fixed |
tapT |
Value: 1 Type: Real Description: Defines temperature of heatPort between inlet and outlet temperature |
usePressureIncreaseInput |
Value: false Type: Boolean Description: Enable / disable pressure increase input |
constantPressureIncrease |
Value: Type: Pressure (Pa) Description: Pressure increase |
T |
Type: Temperature (K) Description: Outlet temperature of medium |
---|---|
T_a |
Type: Temperature (K) Description: Temperature at flowPort_a |
T_b |
Type: Temperature (K) Description: Temperature at flowPort_b |
dT |
Type: TemperatureDifference (K) Description: Temperature increase of coolant in flow direction |
flowPort_a |
Type: FlowPort_a Description: Filled flow port (used upstream) |
|
---|---|---|
flowPort_b |
Type: FlowPort_b Description: Hollow flow port (used downstream) |
|
pressureIncrease |
Type: RealInput Description: 'input Real' as connector |
medium |
Type: Medium Description: Medium in the component |
---|