WOLFRAM SYSTEM MODELER
TwoMassesSimple conduction demo |
SystemModel["Modelica.Thermal.HeatTransfer.Examples.TwoMasses"]
This information is part of the Modelica Standard Library maintained by the Modelica Association.
This example demonstrates the thermal response of two masses connected by a conducting element. The two masses have the same heat capacity but different initial temperatures (T1=100 [degC], T2= 0 [degC]). The mass with the higher temperature will cool off while the mass with the lower temperature heats up. They will each asymptotically approach the calculated temperature T_final_K (T_final_degC) that results from dividing the total initial energy in the system by the sum of the heat capacities of each element.
Simulate for 5 s and plot the variables
mass1.T, mass2.T, T_final_K or
Tsensor1.T, Tsensor2.T, T_final_degC
T_final_K |
Value: Type: Temperature (K) Description: Projected final temperature |
---|
mass1 |
Type: HeatCapacitor Description: Lumped thermal element storing heat |
|
---|---|---|
mass2 |
Type: HeatCapacitor Description: Lumped thermal element storing heat |
|
conduction |
Type: ThermalConductor Description: Lumped thermal element transporting heat without storing it |
|
Tsensor1 |
Type: TemperatureSensor Description: Absolute temperature sensor in degCelsius |
|
Tsensor2 |
Type: TemperatureSensor Description: Absolute temperature sensor in degCelsius |