WOLFRAM SYSTEM MODELER

FixedHeatFlow

Fixed heat flow boundary condition

Wolfram Language

In[1]:=
SystemModel["Modelica.Thermal.HeatTransfer.Sources.FixedHeatFlow"]
Out[1]:=

Information

This information is part of the Modelica Standard Library maintained by the Modelica Association.

This model allows a specified amount of heat flow rate to be "injected" into a thermal system at a given port. The constant amount of heat flow rate Q_flow is given as a parameter. The heat flows into the component to which the component FixedHeatFlow is connected, if parameter Q_flow is positive.

If parameter alpha is <> 0, the heat flow is multiplied by (1 + alpha*(port.T - T_ref)) in order to simulate temperature dependent losses (which are given with respect to reference temperature T_ref).

Parameters (3)

Q_flow

Value:

Type: HeatFlowRate (W)

Description: Fixed heat flow rate at port

T_ref

Value: 293.15

Type: Temperature (K)

Description: Reference temperature

alpha

Value: 0

Type: LinearTemperatureCoefficient (1/K)

Description: Temperature coefficient of heat flow rate

Connectors (1)

port

Type: HeatPort_b

Description: Thermal port for 1-dim. heat transfer (unfilled rectangular icon)

Used in Examples (2)

HeatingSystem

Modelica.Fluid.Examples

Simple model of a heating system

IncompressibleFluidNetwork

Modelica.Fluid.Examples

Multi-way connections of pipes and incompressible medium model