WOLFRAM SYSTEM MODELER
TwoWayFlowControlValveAssembly with a restriction and a pressure compensating valve |
SystemModel["Hydraulic.Valves.FlowControl.TwoWayFlowControlValve"]
medium |
Value: Oil() Type: Medium Description: Medium in the component |
---|---|
ARestriction |
Value: 0.001 Type: Area (m²) Description: Opening area of restriction |
CdRestriction |
Value: 0.62 Type: Real Description: Coefficient of discharge for the restriction |
V |
Value: 0.0001 Type: Volume (m³) Description: Volume of assembly |
Gleak |
Value: 1e-020 Type: PressureDependentLeakage (m³/(s⋅Pa)) Description: Leakage between ports |
pMaxCompensator |
Value: 200000.0 Type: Pressure (Pa) Description: Pressure when compensator valve is fully closed |
pMinCompensator |
Value: 100000.0 Type: Pressure (Pa) Description: Pressure when compensator valve starts to close |
t1Compensator |
Value: 0.01 Type: Time (s) Description: Time constant for first-order system of compensator valve |
AMaxCompensator |
Value: 0.001 Type: Area (m²) Description: Maximum opening area of compensator valve |
CdCompensator |
Value: 0.62 Type: Real Description: Coefficient of discharge for the compensator valve opening |
medium |
Type: Medium Description: Medium in the component |
|
---|---|---|
pressureCompensatingValve |
Type: PressureCompensatingValveNormallyOpen Description: Pressure valve, controlled by the pressure difference between the ports |
|
restrictionTurbulent1 |
Type: RestrictionTurbulent Description: Turbulent restriction |
|
volume |
Type: Volume Description: Fixed volume with fluid storage |