WOLFRAM SYSTEM MODELER
    DCPM_QuasiStaticTest example: Compare DCPM motors transient - quasi-static  | 
     | 
SystemModel["Modelica.Electrical.Machines.Examples.DCMachines.DCPM_QuasiStatic"]

This information is part of the Modelica Standard Library maintained by the Modelica Association.
Test example: Compare DCPM motors transient and quasi-static| Va | 
         Value: 100 Type: Voltage (V) Description: Actual armature voltage  | 
    
|---|---|
| Ve | 
         Value: 100 Type: Voltage (V) Description: Actual excitation voltage  | 
    
| w0 | 
         Value: Modelica.Units.Conversions.from_rpm(1500) Type: AngularVelocity (rad/s) Description: No-load speed  | 
    
| TLoad | 
         Value: 63.66 Type: Torque (N⋅m) Description: Nominal load torque  | 
    
| JLoad | 
         Value: 0.15 Type: Inertia (kg⋅m²) Description: Load's moment of inertia  | 
    
| dcpmData | 
         Value: Type: DcPermanentMagnetData Description: DC machine data  | 
    
| dcpm1 | 
         Type: DC_PermanentMagnet Description: Permanent magnet DC machine  | 
    |
|---|---|---|
| armatureVoltage | 
         Type: ConstantVoltage Description: Source for constant voltage  | 
    |
| groundArmature | 
         Type: Ground Description: Ground node  | 
    |
| loadInertia1 | 
         Type: Inertia Description: 1D-rotational component with inertia  | 
    |
| loadTorque1 | 
         Type: Torque Description: Input signal acting as external torque on a flange  | 
    |
| pulse | 
         Type: Pulse Description: Generate pulse signal of type Real  | 
    |
| dcpm2 | 
         Type: DC_PermanentMagnet Description: Quasi-static permanent magnet DC machine  | 
    |
| loadInertia2 | 
         Type: Inertia Description: 1D-rotational component with inertia  | 
    |
| loadTorque2 | 
         Type: Torque Description: Input signal acting as external torque on a flange  | 
    |
| dcpmData | 
         Type: DcPermanentMagnetData Description: DC machine data  |