Calculation of mean convective heat transfer coefficient kc of a straight pipe at an uniform wall temperature or uniform heat flux and for a hydrodynamically developed or undeveloped overall fluid flow with neglect or consideration of pressure loss influence. Note that additionally a failure status is observed in this function to check if the intended boundary conditions are fulfilled. See more information .
IN_con |
Type: kc_overall_IN_con Description: Input record for function kc_overall |
---|---|
IN_var |
Type: kc_overall_IN_var Description: Input record for function kc_overall |
kc |
Type: CoefficientOfHeatTransfer (W/(m²⋅K)) Description: Convective heat transfer coefficient |
---|---|
Pr |
Type: PrandtlNumber Description: Prandtl number |
Re |
Type: ReynoldsNumber Description: Reynolds number |
Nu |
Type: NusseltNumber Description: Nusselt number |
failureStatus |
Type: Real Description: 0== boundary conditions fulfilled | 1== failure >> check if still meaningful results |
2016-04-11 Stefan Wischhusen: Removed singularity for Re at zero mass flow rate.