kc_twoPhaseOverall_KCLocal two phase heat transfer coefficient of straight pipe | horizontal or vertical boiling | horizontal condensation |
|

SystemModel["Modelica.Fluid.Dissipation.HeatTransfer.StraightPipe.kc_twoPhaseOverall_KC"]

This information is part of the Modelica Standard Library maintained by the Modelica Association.
Calculation of local two phase heat transfer coefficient kc_2ph for (horizontal/vertical) boiling or (horizontal) condensation for an overall flow regime. See more information .
| IN_con |
Type: kc_twoPhaseOverall_KC_IN_con Description: Input record for function kc_twoPhaseOverall_KC |
|---|---|
| IN_var |
Type: kc_twoPhaseOverall_KC_IN_var Description: Input record for function kc_twoPhaseOverall_KC |
| kc |
Type: CoefficientOfHeatTransfer (W/(m²⋅K)) Description: Local two phase heat transfer coefficient |
|---|
2016-04-11 Stefan Wischhusen: Removed singularity for Re at zero mass flow rate.