WOLFRAM SYSTEM MODELER
dp_internalFlowOverall_DPPressure loss of internal flow | calculate pressure loss | overall flow regime | surface roughness | several geometries |
SystemModel["Modelica.Fluid.Dissipation.PressureLoss.Channel.dp_internalFlowOverall_DP"]
This information is part of the Modelica Standard Library maintained by the Modelica Association.
Calculation of pressure loss for an internal flow through different geometries at overall flow regime for incompressible and single-phase fluid flow considering surface roughness.
Generally this function is numerically best used for the incompressible case, where the mass flow rate (m_flow) is known (as state variable) in the used model and the corresponding pressure loss (DP) has to be calculated. On the other hand the function dp_internalFlowOverall_MFLOW is numerically best used for the compressible case if the pressure loss (dp) is known (out of pressures as state variable) and the mass flow rate (M_FLOW) has to be calculated. See more information.
IN_con |
Type: dp_internalFlowOverall_IN_con Description: Input record for function dp_internalFlowOverall_DP |
---|---|
IN_var |
Type: dp_internalFlowOverall_IN_var Description: Input record for function dp_internalFlowOverall_DP |
m_flow |
Type: MassFlowRate (kg/s) Description: Mass flow rate |
DP |
Type: Pressure (Pa) Description: Output for function dp_internalFlowOverall_DP |
---|