WOLFRAM SYSTEM MODELER
    dp_twoPhaseChisholm_DPFrictional pressure loss of straight pipe for two phase flow according to Chisholm correlation | calculate pressure loss | overall flow regime  | 
     | 

SystemModel["Modelica.Fluid.Dissipation.Utilities.Functions.PressureLoss.TwoPhase.dp_twoPhaseChisholm_DP"]

| IN_con | 
         Type: TwoPhaseFlow_con Description: Base record for two phase Flow  | 
    
|---|---|
| IN_var | 
         Type: TwoPhaseFlow_var Description: Base record for two phase flow  | 
    
| m_flow | 
         Type: MassFlowRate (kg/s) Description: Mass flow rate  | 
    
| DP | 