Information

This block reads data from multiple items of type Real from the OPC server it is connected to. It inherits the properties of the partial model Sampler, which contains parameters such as samplePeriod and itemName that determine how often and from which OPC items the data should be read.

At every sampling instant, external function readExternalReal is called from within the block.

Relevant Parameters

  • samplePeriod: determines how often to sample data from the OPC item
  • startTime: when the block should start to read data
  • itemName: which OPC items to read data from

Interfaces

  • y: a Real array output of the same size as itemName, which is the sampled signals
  • serverID: the connector that connects the block to the OPC server component

Parameters (4)

samplePeriod

Value:

Type: Time (s)

Description: Sample period of component

startTime

Value: 0

Type: Time (s)

Description: First sample time instant

itemName

Value: {""}

Type: String[:]

Description: The OPC items that data should be written to or read from

y_start

Value: fill(0, size(itemName, 1))

Type: Real[size(itemName, 1)]

Description: initial value of output signal

Connectors (2)

serverID

Type: BlockConnector

Description: The unique ID of the server the block is connected to

y

Type: RealOutput[size(itemName, 1)]

Description: The data read from the item on the OPC server

Components (1)

readItem

Type: Read[size(itemName, 1)]

Description: A block for reading data from items on an OPC server at intervals determined by parameter samplePeriod

Used in Examples (1)

MultipleItems

OPCClassic.Examples

Example that demonstrates how multiple items can be read using the same component