WOLFRAM SYSTEM MODELER
dp_curvedOverall_MFLOWPressure loss of curved bend | calculate mass flow rate | overall flow regime | surface roughness |
SystemModel["Modelica.Fluid.Dissipation.PressureLoss.Bend.dp_curvedOverall_MFLOW"]
This information is part of the Modelica Standard Library maintained by the Modelica Association.
Calculation of pressure loss in curved bends at overall flow regime for incompressible and single-phase fluid flow through circular cross sectional area considering surface roughness.
Generally this function is numerically best used for the compressible case if the pressure loss (dp) is known (out of pressures as state variable) and the mass flow rate (M_FLOW) has to be calculated. On the other hand the function dp_curvedOverall_DP is numerically best used for the incompressible case, where the mass flow rate (m_flow) is known (as state variable) in the used model and the corresponding pressure loss (DP) has to be calculated. See more information .
IN_con |
Type: dp_curvedOverall_IN_con Description: Input record for function dp_curvedOverall_MFLOW |
---|---|
IN_var |
Type: dp_curvedOverall_IN_var Description: Input record for function dp_curvedOverall_MFLOW |
dp |
Type: Pressure (Pa) Description: Pressure loss |
M_FLOW |
Type: MassFlowRate (kg/s) Description: Output for function dp_curvedOverall_MFLOW |
---|