WOLFRAM SYSTEM MODELER

dp_edgedOverall_MFLOW

Pressure loss of edged bend | calculate mass flow rate | overall flow regime | surface roughness

Wolfram Language

In[1]:=
SystemModel["Modelica.Fluid.Dissipation.PressureLoss.Bend.dp_edgedOverall_MFLOW"]
Out[1]:=

Information

This information is part of the Modelica Standard Library maintained by the Modelica Association.

Calculation of pressure loss in edged bends with sharp corners at overall flow regime for incompressible and single-phase fluid flow through circular cross sectional area considering surface roughness.

There are larger pressure losses in an edged bend compared to a curved bend under the same conditions. The effect of a sharp corner in an edged bend on the pressure loss is much larger than the influence of surface roughness.

Generally this function is numerically best used for the compressible case if the pressure loss (dp) is known (out of pressures as state variable) and the mass flow rate (M_FLOW) has to be calculated. On the other hand the function dp_edgedOverall_DP is numerically best used for the incompressible case, where the mass flow rate (m_flow) is known (as state variable) in the used model and the corresponding pressure loss (DP) has to be calculated. See more information .

Syntax

M_FLOW = dp_edgedOverall_MFLOW(IN_con, IN_var, dp)

Inputs (3)

IN_con

Type: dp_edgedOverall_IN_con

Description: Input record for function dp_edgedOverall_MFLOW

IN_var

Type: dp_edgedOverall_IN_var

Description: Input record for function dp_edgedOverall_MFLOW

dp

Type: Pressure (Pa)

Description: Pressure loss

Outputs (1)

M_FLOW

Type: MassFlowRate (kg/s)

Description: Output for function dp_edgedOverall_MFLOW

Revisions

2014-12-02 Stefan Wischhusen: Changed transition regimes for laminar to highly turbulent domain.