WOLFRAM SYSTEM MODELER

Read

Adds reading of a Boolean scalar node to a ReadNodeList

Wolfram Language

In[1]:=
SystemModel["OPCUA.Components.Clocked.BooleanSignals.Read"]
Out[1]:=

Information

This component reads scalar data from the specified node as part of the request defined by the ReadNodeList it's connected to.

See OPCUA.Interfaces.Node for how to specify the node identity and handle errors.

Parameters (6)

nodeIDType

Value:

Type: UANodeIdType

Description: The node identifier type

nodeID

Value:

Type: String

Description: The node identifier

nodeNamespace

Value:

Type: Integer

Description: The node namespace

errorHandling

Value:

Type: ErrorHandling

Description: How to handle node errors (request errors are handled by the connected Read/WriteNodeList component)

enableSourceTimestamp

Value: false

Type: Boolean

Description: Enable source timestamp output

enableServerTimestamp

Value: false

Type: Boolean

Description: Enable server timestamp output

Connectors (7)

severity

Type: SeverityOutput

Description: Node level status severity

list_a

Type: List_a

Description: Connector for propagating node registrations to a NodeList

sourceTimestamp

Type: TimestampOutput

Description: 'output Timestamp' as connector

serverTimestamp

Type: TimestampOutput

Description: 'output Timestamp' as connector

internalSourceTimestamp

Type: TimestampInput

Description: 'input Timestamp' as connector

internalServerTimestamp

Type: TimestampInput

Description: 'input Timestamp' as connector

y

Type: BooleanOutput

Description: Clocked output signal

Components (1)

nodeObj

Type: NodeObject

Used in Components (1)

Read

OPCUA.Components.Unclocked.BooleanSignals

Adds reading of a Boolean scalar node to a ReadNodeList