WOLFRAM SYSTEM MODELER
PilotOperatedSequenceValvePressure valve, controlled by the pressure at the port_pilot |
|
SystemModel["Hydraulic.Valves.PressureControl.PilotOperatedSequenceValve"]

| medium |
Value: Oil() Type: Medium Description: Medium in the component |
|---|---|
| V |
Value: 0.0001 Type: Volume (m³) Description: Volume of control valve |
| Gleak |
Value: 9.999999999999999e-21 Type: PressureDependentLeakage (m³/(s⋅Pa)) Description: Leakage between ports |
| pMax |
Value: 21000000.0 Type: Pressure (Pa) Description: Pressure when valve is fully opened |
| pMin |
Value: 20000000.0 Type: Pressure (Pa) Description: Pressure when valve starts to open |
| t1 |
Value: 0.01 Type: Time (s) Description: Time constant for first-order system |
| AMax |
Value: 0.001 Type: Area (m²) Description: Maximum opening area |
| Cd |
Value: 0.62 Type: Real Description: Coefficient of discharge for the opening |
| medium |
Type: Medium Description: Medium in the component |
|
|---|---|---|
| pressureCompensatingValve |
Type: PressureCompensatingValveNormallyClosed Description: Static pressure compensating valve |
|
| volume_a |
Type: Volume Description: Fixed volume with fluid storage |
|
| volume_b |
Type: Volume Description: Fixed volume with fluid storage |
|
| tank1 |
Type: Tank Description: Simple tank with constant pressure |
|
Hydraulic.Examples.MultipleActuators Example circuit with two cylinders working in a sequence |