WOLFRAM SYSTEM MODELER
PilotOperatedSequenceValvePressure valve, controlled by the pressure at the port_pilot |
![]() |
SystemModel["Hydraulic.Valves.PressureControl.PilotOperatedSequenceValve"]
medium |
Value: Oil() Type: Medium Description: Medium in the component |
---|---|
V |
Value: 0.0001 Type: Volume (m³) Description: Volume of control valve |
Gleak |
Value: 9.999999999999999e-21 Type: PressureDependentLeakage (m³/(s·Pa)) Description: Leakage between ports |
pMax |
Value: 21000000.0 Type: Pressure (Pa) Description: Pressure when valve is fully opened |
pMin |
Value: 20000000.0 Type: Pressure (Pa) Description: Pressure when valve starts to open |
t1 |
Value: 0.01 Type: Time (s) Description: Time constant for first-order system |
AMax |
Value: 0.001 Type: Area (m²) Description: Maximum opening area |
Cd |
Value: 0.62 Type: Real Description: Coefficient of discharge for the opening |
![]() |
Hydraulic.Examples.MultipleActuators Example circuit with two cylinders working in a sequence |