WOLFRAM SYSTEM MODELER
    SequenceValvePressure valve, controlled by the pressure at port_a  | 
     | 
SystemModel["Hydraulic.Valves.PressureControl.SequenceValve"]

| medium | 
         Value: Oil() Type: Medium Description: Medium in the component  | 
    
|---|---|
| V | 
         Value: 0.0001 Type: Volume (m³) Description: Volume of control valve  | 
    
| Gleak | 
         Value: 9.999999999999999e-21 Type: PressureDependentLeakage (m³/(s⋅Pa)) Description: Leakage between ports  | 
    
| pMax | 
         Value: 21000000.0 Type: Pressure (Pa) Description: Pressure when valve is fully opened  | 
    
| pMin | 
         Value: 20000000.0 Type: Pressure (Pa) Description: Pressure when valve starts to open  | 
    
| t1 | 
         Value: 0.01 Type: Time (s) Description: Time constant for first-order system  | 
    
| AMax | 
         Value: 0.001 Type: Area (m²) Description: Maximum opening area  | 
    
| Cd | 
         Value: 0.62 Type: Real Description: Coefficient of discharge for the opening  | 
    
| medium | 
         Type: Medium Description: Medium in the component  | 
    |
|---|---|---|
| pressureCompensatingValve | 
         Type: PressureCompensatingValveNormallyClosed Description: Static pressure compensating valve  | 
    |
| volume_a | 
         Type: Volume Description: Fixed volume with fluid storage  | 
    |
| volume_b | 
         Type: Volume Description: Fixed volume with fluid storage  | 
    |
| tank1 | 
         Type: Tank Description: Simple tank with constant pressure  | 
    
| 
        
         Hydraulic.Examples.MultipleActuators Example circuit with two cylinders working in a sequence  |