WOLFRAM SYSTEM MODELER
    DCVE22Electrically actuated proportional valve with two ports and two states  | 
     | 

SystemModel["Hydraulic.Valves.DirectionalControl.ConventionalSolenoidActuation.DCVE22"]




| medium | 
         Value: Oil() Type: Medium Description: Medium in the component  | 
    
|---|---|
| Gleak | 
         Value: 1e-020 Type: PressureDependentLeakage (m³/(s⋅Pa)) Description: Leakage between orifices  | 
    
| overlap | 
         Value: 0 Type: Length (m) Description: Spool overlap, a number between -1 and 1; 0 if no overlap  | 
    
| AMax | 
         Value: 0.001 Type: Area (m²) Description: Maximum opening area  | 
    
| Cd | 
         Value: 0.62 Type: Real Description: Coefficient of discharge for the opening  | 
    
| V | 
         Value: 0.0001 Type: Volume (m³) Description: Volume of control valve  | 
    
| Un | 
         Value: 1 Type: Voltage (V) Description: Spool nominal voltage  | 
    
| f | 
         Value: 80 Type: Frequency (Hz) Description: Spool resonance frequency  | 
    
| d | 
         Value: 0.9 Type: Damping (s⁻¹) Description: Spool damping  | 
    
| medium | 
         Type: Medium Description: Medium in the component  | 
    |
|---|---|---|
| volume_a | 
         Type: Volume Description: Fixed volume with fluid storage  | 
    |
| volume_b | 
         Type: Volume Description: Fixed volume with fluid storage  | 
    |
| flow_ab | 
         Type: ControlledOrifice Description: Controlled restriction  | 
    |
| spool | 
         Type: SpoolE Description: An electrical spool with second-order characteristics  | 
    
| 
        
         Hydraulic.Examples.Accumulators Example circuit with an accumulator and cylinder  |